NanoStationM/locoM Series Quick Start Guide (2024)

NSM2/NSM3/NSM365/NSM5

NanoStationM/locoM Series Quick Start Guide (1)
NanoStation​M2/M3/M365/M5
NanoStationM/locoM Series Quick Start Guide (2)
Zip Tie
NanoStationM/locoM Series Quick Start Guide (3)
PoE (24V, 0.5A) with Mounting Bracket
NanoStationM/locoM Series Quick Start Guide (4)
Power Cord

locoM2/locoM5

locoM9

NanoStationM/locoM Series Quick Start Guide (9)
NanoStationlocoM9
NanoStationM/locoM Series Quick Start Guide (10)
Zip Tie
NanoStationM/locoM Series Quick Start Guide (11)
PoE (24V, 0.5A) with Mounting Bracket
NanoStationM/locoM Series Quick Start Guide (12)
Power Cord
  • Shielded Category 5 (or above) cabling with drain wire should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE.
  • We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit ui.com/toughcable

  • Surge protection should be used for all outdoor installations. We recommend that you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation and the other at the entry point to the building. The ETH-SP will absorb power surges and safely discharge them into the ground.

NanoStationM/locoM Series Quick Start Guide (13)

NSM2/NSM3/NSM365/NSM5/locoM2/locoM5

NanoStationM/locoM Series Quick Start Guide (14)

NanoStationM/locoM Series Quick Start Guide (15)

NanoStationM/locoM Series Quick Start Guide (16)

Power LED

The LED will light green when the device is connected to a power source.

NanoStationM/locoM Series Quick Start Guide (17)

LAN1 LED

The LED will light steady green when an active Ethernet connection is made to the Main/LAN port and flash when there is activity.

NanoStationM/locoM Series Quick Start Guide (18)

LAN2 LED

(NanoStation M2/M3/M5 only) The LED will light steady green when an active Ethernet connection is made to the Secondary port and flash when there is activity.

NanoStationM/locoM Series Quick Start Guide (19)

Signal LEDs

In airOS®, you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds. The default values are shown below:

NanoStationM/locoM Series Quick Start Guide (20)

NanoStationM/locoM Series Quick Start Guide (21)

Secondary Port

(NanoStationM2/M3/M5 only) This 10/100 Ethernet port is used for bridging and supports software-configurable PoE passthrough.

NanoStationM/locoM Series Quick Start Guide (22)

Note: To use PoE passthrough on the Secondary port, a 24V, 1A PoE adapter is required.

NanoStationM/locoM Series Quick Start Guide (23)

Main/LAN* Port

This 10/100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.

NanoStationM/locoM Series Quick Start Guide (24)

Reset Button

To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the PoE adapter.

* The Main port is labeled LAN on the NanoStationlocoM2/M5.

locoM9

NanoStationM/locoM Series Quick Start Guide (25)

NanoStationM/locoM Series Quick Start Guide (26)

NanoStationM/locoM Series Quick Start Guide (27)

Power LED

The LED will light green when the device is connected to a power source.

NanoStationM/locoM Series Quick Start Guide (28)

LAN1 LED

The LED will light steady green when an active Ethernet connection is made to the Main/LAN port and flash when there is activity.

NanoStationM/locoM Series Quick Start Guide (29)

Signal LEDs

In airOS®, you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds. The default values are shown below:

NanoStationM/locoM Series Quick Start Guide (30)

NanoStationM/locoM Series Quick Start Guide (31)

RP-SMA Antenna Connector

Reserved for future use.
NanoStationM/locoM Series Quick Start Guide (32)

Main/LAN Port

This 10/100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server.

NanoStationM/locoM Series Quick Start Guide (33)

Reset Button

To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on. Alternatively, the device may be reset remotely via a Reset button located on the bottom of the PoE adapter.

  1. NanoStationM/locoM Series Quick Start Guide (34)

  2. NanoStationM/locoM Series Quick Start Guide (35)

  3. NanoStationM/locoM Series Quick Start Guide (36)

  4. NanoStationM/locoM Series Quick Start Guide (37)

  5. NanoStationM/locoM Series Quick Start Guide (38)

  6. NanoStationM/locoM Series Quick Start Guide (39)

NanoStationM/locoM Series Quick Start Guide (40)

WARNING: The switch port must comply with the power specifications listed in this Quick Start Guide.

NanoStationM/locoM Series Quick Start Guide (41)

OR

NanoStationM/locoM Series Quick Start Guide (42)

Optional

NanoStationM/locoM Series Quick Start Guide (43)

Verify connectivity in the airOS Configuration Interface.

  1. Make sure that your host system is connected via Ethernet to the device.
  2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
  3. Launch your web browser and type https://192.168.1.20 in the address field. Press enter (PC) or return (Mac).

    NanoStationM/locoM Series Quick Start Guide (44)

  4. Enter ubnt in the Username and Password fields. Select your Country and Language. You must agree to the Terms of Use to use the product. Click Login.

The airOS Configuration Interface will appear, allowing you to customize your settings as needed. For details, refer to the User Guide available at ui.com/download/airmax

You can also manage your device using the Ubiquiti Internet Service Provider. Setup using the UISP app requires the U-Installer, sold separately.

Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.

The Antenna Gain and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements.

NanoStationM2/M3/M365/M5

Dimensions

294 x 30 x 80 mm

(11.57 x 1.18 x 3.15")

Weight

NSM2/NSM5 0.4 kg (14.11 oz)
NSM3/NSM3650.5 kg (17.64 oz)

Gain

NSM2 11 dBi
NSM3/NSM365 13.7 dBi
NSM516 dBi

Networking Interface

(2) 10/100 Ethernet Ports

Max. Power Consumption

8W

Power Supply

24V, 0.5A PoE Adapter (Included)

Power Method

Passive PoE (Pairs 4, 5+; 7, 8 Return)

Mounting

Pole Mounting Kit Included

Operating Temperature

-30 to 75° C (-22 to 167° F)

Operating Humidity

5 to 95% Noncondensing

NSM2/NSM3/NSM365 Operating Frequency (MHz)

NSM2

2412 - 2462

NSM3

3400 - 3700

NSM365

3650 - 3675

NSM5 Operating Frequency (MHz)

Worldwide

5150 - 5875

EU

5150 - 5350, 5470 - 5725, 5725 - 5875

USA

U-NII-1

5150 - 5250

U-NII-2A

5250 - 5350

U-NII-2C

5470 - 5725

U-NII-3

5725 - 5850

CA

5470 - 5600, 5650 - 5725, 5725 - 5850

NanoStationlocoM2/M5/M9

Dimensions

locoM9164 x 72 x 199 mm
(6.46 x 2.83 x 7.83")
locoM2/locoM5163 x 31 x 80 mm
(6.42 x 1.22 x 3.15")

Weight

locoM90.9 kg (31.75 oz)
locoM2/locoM50.18 kg (6.35 oz)

Gain

locoM9/locoM2 8 dBi
locoM513 dBi

Networking Interface

(1) 10/100 Ethernet Port

Max. Power Consumption

locoM96.5W
locoM2/locoM55.5W

Power Supply

24V, 0.5A PoE Adapter (Included)

Power Method

Passive PoE (Pairs 4, 5+; 7, 8 Return)

Mounting

Pole Mounting Kit Included

Operating Temperature

-30 to 75° C (-22 to 167° F)

Operating Humidity

5 to 95% Noncondensing

locoM2 Operating Frequency (MHz)

Worldwide

2412 - 2462

locoM5 Operating Frequency (MHz)

Worldwide

5150 - 5875

EU

5150 - 5350, 5470 - 5725, 5725 - 5875

USA

U-NII-1

5150 - 5250

U-NII-2A

5250 - 5350

U-NII-2C

5470 - 5725

U-NII-3

5725 - 5850

CA

5470 - 5600, 5650 - 5725, 5725 - 5850

locoM9 Operating Frequency (MHz)

Worldwide

902 - 928

© Ubiquiti Inc. All rights reserved.

NanoStationM/locoM Series Quick Start Guide (2024)
Top Articles
Latest Posts
Article information

Author: Golda Nolan II

Last Updated:

Views: 6432

Rating: 4.8 / 5 (58 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Golda Nolan II

Birthday: 1998-05-14

Address: Suite 369 9754 Roberts Pines, West Benitaburgh, NM 69180-7958

Phone: +522993866487

Job: Sales Executive

Hobby: Worldbuilding, Shopping, Quilting, Cooking, Homebrewing, Leather crafting, Pet

Introduction: My name is Golda Nolan II, I am a thoughtful, clever, cute, jolly, brave, powerful, splendid person who loves writing and wants to share my knowledge and understanding with you.